Radiant Herringbone

SPACE-RAY Herringbone Tube heaters have many applications from factories and warehouses to sports halls, aircraft hangers, supermarkets, exhibition halls and retail premises. So no matter what the use, size or shape of your building you can rest assured that SPACE-RAY Radiant Herringbone heaters will suit your needs.
How do SPACE-RAY Radiant Tube heaters work? A gas fired flame within the Calorised
Emitter Tube causes the heat to radiate invisible "black heat"
energy. This energy gently warms surfaces and people without heating the air
directly. Therefore SPACE-RAY Radiant Tube Heaters are highly fuel efficient
and are an ideal total heating system or for zone/spot heating.
General Specification
|
SPACE-RAY Radiant Herringbone
System - Technical Specification |
||||||||
| Model |
SRL / CBU09 HB |
SRL / CBU12-HB |
SRL / CBU15-HB |
SRL / SRU25-HB |
SRL / SRU30-HB |
SRL / SRU35-HB |
SRL / SRU40-HB |
SRL / SRU45-HB |
| Input - kW |
9.0 |
11.40 |
15.0 |
23.0 |
29.20 |
34.50 |
42.20 |
47.0 |
| Length -"U"
mm |
3100 mm |
5385mm |
5510mm |
6970mm |
||||
Length -Linear
mm |
5230mm |
9800mm |
9740mm |
12800mm |
||||
| Width - "U"
mm |
460mm |
715mm |
||||||
| Width - Linear
mm |
340mm |
|||||||
Height -"U"
mm |
175mm |
210mm |
||||||
| Height -Linear
mm |
180mm |
|||||||
| Weight - "U" kg | 29kg |
45kg |
68kg |
81kg |
||||
| Weight
- Linear kg |
25kg |
42kg |
54kg |
70kg |
||||
| Gas Connection |
All Models R -1/2" BSP external |
|||||||
| Supply Pressure |
Natural Gas - Min 17mbar, Max 25mbar;
Propane - Min 25mbar, Max 45mbar; Butane - Min 20mbar, Max 35mbar |
|||||||
| Electrical
Supply |
230v~50hz 125w, Current rating (Each
Burner) at 0.55A, Fuse externally (Each Burner)3A |
|||||||
Fan No 1 - 230v~50hz, 60W Current Rating
0.48A |
||||||||
Fan No 2 - 230v~50hz, Current Rating
1.80A |
||||||||
Fan No 3 - 230v~50hz, Current Rating
3.30A |
||||||||
Air Inlet
Connection |
All Models - 101.6mm |
|||||||
Recommended
Mouting Height Range (General Guidance Only) |
||||||||
| Model |
SRL / CBU09 HB |
SRL / CBU12-HB |
SRL / CBU15-HB |
SRL / SRU25-HB |
SRL / SRU30-HB |
SRL / SRU35-HB |
SRL / SRU40-HB |
SRL / SRU45-HB |
Horizontal
|
2.4m - 6.0m |
3.0m - 8.0m |
3.8m - 10.0m |
4.0m - 12.5m |
4.8m - 13.5m |
5.6m - 15m |
||
Angle >
30 Degrees |
2.1m - 4.5m |
2.7m - 5.0m |
3.3m - 7.0m |
3.7m - 8.0m |
4.0m - 9.0m |
4.8m - 11m |
||
| Minimum
Clearance to Combustible Material - (mm) |
||||||||
|
Model |
SRL / CBU09 HB |
SRL / CBU12-HB |
SRL / CBU15-HB |
SRL / SRU25-HB |
SRL / SRU30-HB |
SRL / SRU35-HB |
SRL / SRU40-HB |
SRL / SRU45-HB |
|
Side |
450 |
450 |
450 |
510 |
760 |
760 |
760 |
760 |
|
Above |
450 |
450 |
450 |
450 |
610 |
610 |
610 |
610 |
|
Below |
1220 |
1220 |
1220 |
1220 |
2285 |
2285 |
2285 |
2285 |
|
End |
450 |
450 |
450 |
510 |
610 |
610 |
610 |
610 |
|
Front |
575 |
575 |
575 |
610 |
760 |
760 |
760 |
760 |
|
Rear |
305 |
305 |
305 |
305 |
380 |
380 |
380 |
380 |
Recommended Ancilleries:
To view and download our Radiant Herringbone brochure, Click Here
To view and download our Radiant Herringbone Installation Guide, Click
Here (This is for all models of SRL/SRU-HB)