Radiant Brooder - SRB40 CE
Return to Agricultural Page
(Click Pictures to Enlarge (No.9 Control and DSI Respectively)
General Specification
SRB40
CE No.5 (Direct Spark Ignition) or No.9 (Pilot) Control Brooder - Specifiction |
||
|
Input Rating |
............. |
12kW |
|
Stock Capacities |
Broilers |
2000 - 3000 |
Pullets |
1500 - 2000 |
|
Turkeys |
750 - 1000 |
|
Ducks |
750 - 1000 |
|
Pheasants |
1500 - 2000 |
|
|
Mounting Height |
............. |
1520mm - 1830mm |
|
Brooder Spacing |
Maximum |
12.2m |
|
Reflector Diameter |
............. |
890mm |
|
Brooder Height |
............. |
460mm |
|
Brooder Weight |
............. |
12.0kg |
|
Shipping Weight |
............. |
18.0kg |
|
Gas Consumption Per Hour |
Propane |
0.43 GPH |
............. |
1.63 L/hr |
|
Natural Gas |
0.40 Therm |
|
............. |
42.2MJ/hr |
|
|
Min Clearance to Combustibles |
Side |
915mm |
Below |
1220mm |
|
Top |
460mm |
|
|
Ventilaton Requirement |
............. |
Refer to Installation Manual |
|
All Models |
Supply Pressure to
Heater |
Burner Setting Pressure |
|
UK |
Natural Gas - 12mbar to 35mbar |
10mbar |
Propane Gas - 37mbar to 50mbar |
25mbar |
|
|
Export |
Details of gas characteristics and supply
pressure to be advised by customer |
|